AgileHub 2.0 – Shelter Modular Data Center Solution

AgileHub 2.0 shelter modular data center - IP65 outdoor cabinet with hybrid AC/DC power for 5G telecom edge sites
From the 5G era, the demand for mixed deployments of DC and AC power devices presents new challenges for the telecom industry. As experts in the field of modular data centers, we closely track the trends of the digital future, focusing on the challenges faced by telecom operators and data center managers.

Our innovative AgileHub solutions effectively addresses mixed-power issues, offering you energy-efficient, convenient, and flexible configurations to better meet both your current and future needs.

Continual Innovation, Continuous Optimization.

Get a Free Quote

Key Advantages & System Highlights

Flexible Cutomization

  • 24U to 42U cabinet with IP65 protected space with all kinds of critical aspects, access control and video monitoring options.
  • Compact outdoor cabinet with built-in standard 19’’ frame, match for most types IT equipment’s installation.
  • Support multiple power system with 48VDC rectifier and AC UPS.

Green Efficiency

  • Better cooling efficiency with wall/rack/Inrow cooling system.
  • Separated cold/hot air management enhance more energy efficiency.
  • High efficient components including inverter compressors, EC fans and green refrigerant.

Smart Management

  • Smart monitoring system fully communicate with all aspects, integration with access control system, provided real-time data at all times.
  • Local and remote monitoring protocol for easy centralized management and continuous monitoring.
Deployment

Quick Deployment

  • Rugged designs suitable for all environments and applications. Outdoors, rooftops, warehouses, oil rigs, remote sites, can provision in any location with no pre-investment.
  • All-in-one design, factory prefab and commissioning enable fast deployment.

Product Features & Technical Specifications

AgileHub precision cooling system - wall mount design with 48VDC/AC power options, operates from -40°C to 55°C for outdoor telecom cabinets

Optimized Efficiency Cooling with Optional AC / DC Power Input

  • 48VDC and 208-240VAC input power type for optional.
  • High dust/water protection rated in package wall mount design, no occupying of U space.
  • Powder coated sheet metal endures harsh environment
  • Green refrigerant is highly efficient and no ODP.
  • Special design working upto -40C~55C.
AgileHub hybrid power system - 48VDC rectifier with EPS inverter, 60kVA UPS in 4U, and lithium-iron battery for AC/DC mixed deployment

Adaptable Hybird Power Solutions Ensure Safety at All Moments

  • Utilizing a 48VDC rectifier combined with an optional EPS inverter power module, support equipment with AC power input. Using the same backup battery system, save U-space and reduces investment costs.
  • Rectifier module / Solar module for options, support multiple types power input.
  • Rack mount AC UPS system upto 60kVA in only 4U height, saving more space for IT equipment.
  • Standard 19’’ rack mount design.
  • Equipped with high performance Lithium-iron battery, provide reliable protection.
  • Support remote monitoring with multi-channel serial port, dry contact, and network interface output.

Various Pre-Defined Cabinets, Fulfill Your Applications.

AgileHub solution includes a variety of predefined configurations with multiple options for key components such as cabinets, air conditioning, power systems, monitoring system, access control, fire protection, etc. to meet your various application needs.

1-Rack MDC with Wall Cooling

1-Rack MDc Rack Cooling

3-Rack MDC Inrow Cooling

Dual Rack MDC Wall Cooling

2-Rack MDC Rack Cooling

3-Rack MDC with Rack Cooling

AgileHub integrated precision cooling - wall mount, rack, and in-row options with Web/SNMP/RS485 monitoring for remote management

Precision Cooling System

  • Wall mount cooling as standard design.
  • Full range rack cooling / inrow cooling options.
  • Built in smart sensors and Web/SNMP/RS485 monitoring access.
  • Work up-to 55C ambient temperature.
AgileHub rugged IT rack system - 1500kg static loading capacity with built-in cold/hot aisle separation and front/rear access for easy service

Rack System

  • Multiple types cabinets idear for Telecom and micro data center applications.
  • Built-in separated cold/hot air management add more efficiency.
  • Configured with front/rear door for easier operation and service.
  • Rugged metal support frame provide max 1500kg static loading capacity.
AgileHub flexible DC/AC power system - modular UPS and 48VDC rectifier with VRLA/lithium battery and plug-and-play lithium pack for telecom

DC/AC Power System

  • Wide range 48VDC Rectifier and modular UPS rack mount options.
  • VRLA / Lithium battery by configuration.
  • Special UPS type Lithium battery pack, plug and play.
  • Basic/Smart PDU per configurations.
  • Built in power distribution panels configurable to T1~T4 uptime level.
AgileHub integrated DCIM system - remote monitoring via web, SMS, email, Modbus-TCP, with access control integration, zero U mounting

DCIM System

  • Full communication to UPS, cooling, power panel, and all type of sensors.
  • Integration with access control system.
  • Rotation bracket mount host, do not occupy U space.
  • Remote accessible from web, SMS, Email, Modbus-TCP.Optional with SNMP.
AgileHub multi-factor access control for shelter - RFID, digital key, mechanical key, and remote access options for cabinet security

Access Control System

  • Multiple lock open methods including RFID, Digital Input, mechanical key, and remote access control type.
  • Same size with normal IT rack lock for easier installation and integration with existing rack system.
  • Integration with access control system for easier management.
AgileHub rack mount fire protection system - early detection with Novec1230/FM200 agent, integrated smart controller for cabinet fire safety

Fire Protection System

  • Standard rack mount design, easy to be installed within the cabinet.
  • Early fire detection system.
  • Built-in Smart controller,activation sensors,releasing valves for easier fire detection and management.
  • Fire agent of Novec1230/FM200.

Resources Download

Product Brochure

Attom AgileHub Shelter Data Center Brochure
Download PDF

User Manual

Attom Micro Data Center User Manual
Download PDF
Please contact ATTOM customer support to download the PDF manual.

White Paper

When Micro Data Center Meets Edge Computing
Download PDF